Product Features / Benefits 主な特長/機能
- 内部x24 + 外部x4の6Gb/s SATA+SASポート
- 内部mini-SAS SFF-8087 x4コネクタ (6)
- Mini-SAS SFF-8088外部コネクタ (1)
- ハーフ・レングス、フル・ハイト (6.6インチ x 4.376インチ)
- x8 PCI Express 2.0 ホスト・インターフェース
- 512MB DDRIIキャッシュ (800MHz)
主なメリット
- 内部接続ドライブ / ストレージおよび外部接続JBOD拡張
- PCI Express® 2.0は、広帯域アプリケーション用に高速のシグナル伝達を提供
- 最大240台の3Gb/sおよび6Gb/s SATAまたはSAS HDDを接続
- LSIアドバンス・ソフトウェア・オプションのサポート
Product Specifications
|
|
| Solution Provided |
Twenty-four port internal/four-port external SATA+SAS solution for internal drive storage and external JBOD expansion using up to 240 SAS and/or SATA devices
|
| Physical Dimensions |
Half-Length, Full Height (6.6" x 4.376") |
| Internal Connectors |
Six Mini-SAS SFF8087 4i internal connectors |
| External Connectors |
One Mini-SAS SFF8088 4x external connector |
| Device Support |
Up to 240 SAS and/or SATA devices |
| Host Bus Type |
x8 lane PCI Express 2.0 Compliant |
| Data Transfer Rates |
Up to 6Gb/s per port |
| I/O Processor/SAS Controller |
LSISAS2108 RAID on Chip (ROC) and LSISAS2x36 Expander |
| Cache Memory |
512MB 800MHz DDR II SDRAM |
| Battery Backup Unit |
LSIiBBU07 or LSIiBBU08, an intelligent battery backup module option that connects remotely to the RAID controller |
| Key RAID Data Protection Features |
- RAID levels 0, 1, 5 and 6
- RAID spans 10, 50 and 60
- Online Capacity Expansion (OCE)
- Online RAID Level Migration (RLM)
- Auto resume after loss of system power during arrays
array rebuild or reconstruction (RLM)
- Single controller Multipathing
- Load Balancing
- Configurable stripe size up to 1MB
- Fast initialization for quick array setup
- Check Consistency for background data integrity
- SSD Support with SSD Guard™
- Patrol read for media scanning and repairing
- 64 logical drive support
- Up to 64TB LUN support
- DDF compliant Configuration on Disk (COD)
- S.M.A.R.T support
- Global and dedicated Hot Spare with Revertible
Hot Spare support – Automatic rebuild – Enclosure affinity – Emergency SATA hot spare for SAS arrays
- Enclosure management
– SES (inband) – SGPIO (sideband)
|
| Operating Temperature |
Maximum ambient: 60°C (45°C w/iBBU) |
| Operating Voltage |
+3.3V |
| Warranty |
3 years, free advanced technical support, advanced replacement option |
| Regulatory Certifications |
EN55022, EN55024, EN60950, EN 61000-3-2, EN 61000-3-3; FCC Class A, Class B; UL1950; UL; CSA C22.2; VCCI; RRL for MIC; BSMI; C-tick |
| RAID Management |
MegaRAID Management Suite - MegaRAID Storage Manager
- MegaCLI (command-line interface)
- WebBIOS
|
| OS Support |
Extensive support includes Microsoft® Windows® Vista/2008/Server 2003/2000/XP, Linux®, Solaris™ (x86), Netware®, FreeBSD®, VMware® and more. * Visit the LSI download Center for the most complete list of supported operating systems: lsi.com/channel/support |
| MTBF |
900,264 Hours |
| Ordering Information |
LSI00211 (Single-pack) |
|
|
Product Brief
|
|
Case Study
Compatibility Document
Miscellaneous
Product Guide
Quick Installation Guide
Solution Brief
Technical Brief
| Type |
Name |
Description |
Release Date |
Size |
 |
Enterprise Hardware RAID and Software RAID Technical Brief |
Hardware RAID is data protection and application acceleration technology delivered on PCI Express based
option cards with related firmware, drivers, utilities and management software. Enterprise hardware RAID
cards have onboard capabilities to perform parity generation and RAID recovery operations, as well as
data, memory and bus management. Software RAID, a subset of the features delivered in hardware RAID, is
usually delivered as part of an operating system and relies on system resources, processors, and memory. Version:March 2012 |
Mar 05, 2012 |
0.85M |
User Guide
| Type |
Name |
Description |
Release Date |
Size |
 |
MegaRAID SAS Software User Guide User Guide |
The MegaRAID SAS Software User Guide documents the utilities used to configure, monitor, and maintain MegaRAID® Serial-attached SCSI (SAS) RAID controllers with RAID control capabilities and the storage-related devices connected to them. This guide describes how to use the MegaRAID Storage Manager™ software, the WebBIOS™ configuration utility, and the MegaRAID command line interface.
Version:Rev F |
Mar 30, 2012 |
30.90M |
 |
MegaRAID SAS Software User Guide User Guide |
The MegaRAID SAS Software User Guide documents the utilities used to configure, monitor, and
maintain MegaRAID® Serial-attached SCSI (SAS) RAID controllers with RAID control capabilities and the
storage-related devices connected to them. This guide describes how to use the MegaRAID Storage Manager™ software, the WebBIOS™ configuration utility, and
the MegaRAID command line interface (CLI).
Version:Rev E |
Dec 15, 2011 |
32.57M |
 |
MegaRAID SAS Software User Guide User Guide |
This guide describes how to use the MegaRAID Storage Manager™ software, the WebBIOS™ configuration utility, and the MegaRAID command line interface (CLI). Version:July 2011 |
Sep 26, 2011 |
27.34M |
 |
MR SAS Device Driver Installation User Guide User Guide |
This manual is the primary reference for the operating system drivers provided with the LSI MegaRAID devices. It describes the drivers for all supported operating systems and explains how to install them. The controller can run under MS-DOS or any DOS-compatible operating system using the standard AT BIOS INT 13h hard disk drive interface. To use the controller with other operating systems, you must install software drivers. Driver files for supported operating systems are available on the Universal Driver Suite CD that accompanied your MegaRAID controller. LSI updates the drivers frequently. To ensure you have the current version of this driver, download the driver from the LSI web site- http---www.lsi.com. Version:Rev. E. |
May 18, 2011 |
399.0K |
 |
MegaRAID 6Gb-s SAS RAID Controllers User Guide User Guide |
Version:Revision E, February 2011 |
Mar 31, 2011 |
0.96M |
|
|
Driver
| Type |
Name |
Description |
Release Date |
Size |
 |
CentOS - 5.0 - 10M12 Driver |
CentOS Driver OS:CentOS 5.5 Version:5.30 Readme Link:Readme |
Mar 04, 2011 |
1.44M |
 |
ClearOS - 5.0 - 10M12 Driver |
ClearOS Driver OS:ClearOS 5.2 Version:5.30 Readme Link:readme |
Mar 04, 2011 |
1.22M |
 |
Debian - 5.0 - 10M12 Driver |
Debian Driver OS:Debian 5.04 - Debian 5.05 - Debian 5.06 - Debian 5.07 Version:5.30 Readme Link:readme |
Mar 04, 2011 |
12.68M |
 |
Fedora 13 - 5.0 - 10M12 Driver |
Fedora 13 Driver OS:Fedora 13 Version:5.30 Readme Link:readme |
Mar 04, 2011 |
393.3K |
 |
Fedora 14 - 5.0 - 10M12 Driver |
Fedora 14 Driver OS:Fedora 14 Version:5.30 Readme Link:readme |
Mar 11, 2011 |
9.72M |
 |
Mandriva 2010 - 5.0 - 10M12 Driver |
Mandriva 2010 Driver OS:Mandriva Free 2010 Version:5.30 Readme Link:readme |
Mar 04, 2011 |
0.53M |
 |
Netware - 4.6 -10M03 Driver |
OS:Netware 6.5 Version:1.13 Readme Link:readme |
Dec 17, 2010 |
20.8K |
 |
Linux - 6.12 update 2 Driver |
RHEL, SLES, XEN Drivers OS:RHEL 4 U7, U8, U9; RHEL 5 U2, U3, U4, U5, U6, U7; RHEL 6, 6.1 (32bit, 64bit); SLES9SP2 32bit; SLES9SP2 64bit; SLES9SP3 32bit; SLES9SP3 64bit; SLES9SP4 32bit; SLES9SP4 64bit; SLES10SP2 32bit; SLES10SP2 64bit; SLES10SP3 32bit; SLES10SP3 64bit; SLES10SP4 32bit; SLES10SP4 64bit; SLES11 GA 32bit; SLES11 GA 64bit; SLES11SP1 32bit; SLES11SP1 64bit; XEN server 5.5; XEN server 5.6fp1; XEN server 5.6; XEN server 6.0 Version:6.12 update 2 Readme Link:read me |
Mar 30, 2012 |
69.38M |
 |
RHEL - 4.6 - 10M09 Driver |
RHEL Drivers OS:RHEL3.0-U9 - RHEL4.0-U5 - RHEL4.0-U6 - RHEL4.0-U7 - RHEL4.0-U8 - RHEL5.0-U1 - RHEL5.0-U2 - RHEL5.0-U3 - RHEL5.0-U4 - RHEL5.0-U5 - RHEL6.0-ga _ RHEL6.0-ga Version:4.38 Readme Link:readme |
Mar 04, 2011 |
6.18M |
 |
Linux - 5.0 - 11M08 Driver |
RHEL, SLES, XEN Drivers OS:RHEL4 U7, U8, U9 - RHEL5 U2, U3, U4, U5, U6, U7 - RHEL6.0, RHEL6.1, RHEL6.2 - SLES9 SP2, SP3, SP4 - SLES10 SP2, SP3, SP4 - SLES11, SP1 - XEN Server 5.5, 5.6, 5.6FP1 Version:6.12 Readme Link: readme |
Jan 30, 2012 |
13.36M |
 |
MegaRAID SAS Driver - Scientific Linux 5.5, Version 5.30 Driver |
OS:Scientific Linux 5.5 Version:5.30 Readme Link:readme |
Mar 04, 2011 |
1.43M |
 |
SCO - 4.5 - 10M03 Driver |
SCO Driver OS:SCO Openserver 6.0 - and Unixware 7.14 Version:4.05 Readme Link:readme |
Dec 17, 2010 |
79.0K |
 |
MegaRAID SAS Driver - SCO, Version 4.05 Driver |
OS:SCO Openserver 6.0 - and Unixware 7.14 - (MegaRAID Release 4.5) Version:4.05 Readme Link:readme |
Dec 17, 2010 |
79.0K |
 |
SCO - 5.0 - 11M06 P1 Driver |
SCO Driver OS:SCO Openserver 6.0 and Unixware 7.14 Version:5.03 Readme Link:readme |
Aug 11, 2011 |
125.0K |
 |
MegaRAID SAS Driver - Slackware 13.0, Version 5.30 Driver |
OS:Slackware 13.0 Version:5.30 Readme Link:readme |
Mar 11, 2011 |
47.11M |
 |
MegaRAID SAS Driver - Slackware 13.1, Version 5.30 Driver |
OS:Slackware 13.1 Version:5.30 Readme Link:readme |
Mar 04, 2011 |
55.13M |
 |
SLES - 4.6 - 10M09 Driver |
SLES Drivers OS:SLES9-sp3-SLES9-sp4-SLES10-sp1-SLES10-sp2-SLES10-sp3- SLES11-ga-SLES11-sp1 Version:4.38 Readme Link:readme |
Mar 04, 2011 |
5.73M |
 |
MegaRAID SAS Driver - Solaris 4.7 Driver |
OS:Solaris 10 x86 Version:4.7 Readme Link:read me |
Mar 30, 2012 |
506.8K |
 |
MegaRAID SAS Driver - Ubuntu 10.04 LTS, Version 5.30 Driver |
OS:Ubuntu 10.04 Version:5.30 Readme Link:readme |
Mar 04, 2011 |
15.78M |
 |
MegaRAID SAS Driver - Ubuntu 10.10, Version 5.30 Driver |
OS:Ubuntu 10.10 Version:5.30 Readme Link:readme |
Mar 04, 2011 |
21.72M |
 |
VMware - MegaRAID Release 4.6 - 10M09 Driver |
VMware Driver - Unsigned OS:VMWare 4.0 and 4.1 Version:4.31 Readme Link:readme |
Dec 17, 2010 |
126.4K |
 |
VMware - MegaRAID Release 5.0 - 11M06 Driver |
VMware Drivers OS:VMware 4.0 and 4.1 Version:5.33 Readme Link: readme |
Aug 11, 2011 |
189.1K |
 |
Windows - 5.0 - 11M08 Driver |
Windows Drivers - Signed OS:Windows 2003 x86 - Windows 2003 x64 -
Windows Vista x86 - Windows Vista x64 -
Windows 2008 x86 - Windows 2008 x64 -
Windows 7 x86 - Windows 7 x64 -
Windows 2008R2
Version:5.2.112 Readme Link:Read Me |
Feb 28, 2012 |
436.7K |
Firmware
| Type |
Name |
Description |
Release Date |
Size |
 |
10M09 P24 Firmware |
Firmware - Support for CacheCade Pro 2.0 with MegaRAID SAS 9280-24i4e; MegaRAID SAS 9280-16i4e; MegaRAID SAS 9260-16i; MegaRAID SAS 9260-4i, MegaRAID SAS 9260-8i, MegaRAID SAS 9260DE-8i, MegaRAID SAS 9261-8i, MegaRAID SAS 9280-4i4e, MegaRAID SAS 9280-8e, MegaRAID SAS 9280DE-8e, MegaRAID SAS 9260CV-4i, MegaRAID SAS 9260CV-8i Version:12.12.0-0091 Readme Link: readme |
Jan 30, 2012 |
2.83M |
Management Software and Tools
Solution Brief
|
|
Cables and Accessories
LSIでは、お客様の現在のシステムに簡単にお使いいただける様々な内部接続ケーブル・オプション (別売) を取り揃えています。また、サーバ障害時や停電時に非常用電源をキャッシュ・メモリに供給してデータ損失を防ぐバッテリー・バックアップ・オプションもご用意しています。
- MegaRAID CacheCade Pro 2.0 Software Packオンライン・ストア
- Remote Battery Kit for LSIiBBU06, LSIiBBU07 and LSIiBBU08オンライン・ストア
|
|
|
|
|