Features
- 16 SFF8088 Mini-SAS wide ports (4 SAS lanes per port)
- "1/2 wide" rack form factor
Benefits
- Easily implemented connection of multiple servers to multiple storage enclosures
- Supports dual switch installations with no additional rack space requirements
- Supports virtualized and tiered storage solutions with SAS and SATA hard drives and SSDs
- Enables fewer, larger storage arrays for efficiency, while easing their management with T-10 compliant zoning
|
|
Product Specifications
|
|
| SAS Compliances |
SAS-2.0
|
| SAS Protocols |
SSP, STP and SMP |
| SAS Ports Configuration |
Sixteen x4 Phy Wide |
| SAS Bandwidths |
Half Duplex Wide Port (4 phys) – 24Gb/s |
Full Duplex Wide Port (4 phys) – 48Gb/s |
|
| Storage Types |
1.5, 3.0 or 6.0Gb/s SAS and/or SATA End Devices |
| Zoning |
T10 Compliant Zoning |
| Zone Groups & Zone Sets |
Embedded SAS Domain Manager (SDM) Up to 192 zone groups Up to 16 zone sets |
| Management Interface |
SAS in-band or 10/100 Ethernet out-of-band |
| Firmware |
Field upgradeable |
| Connectors |
SAS Fourteen x4 SFF8088 (MiniSAS) - Passive connectors Two x4 SFF8088 (MiniSAS) - Active connectors that provide active copper cable support |
Ethernet One RJ-45 |
|
| LED Indicators |
| Activity – 1 per port |
Link/Fault – 1 per port |
|
| Real time clock |
Battery backup RTC |
| Power Consumption |
25 watts nominal (no active cables); 50 watts max |
| Power Supply |
External 12 Volt ±5% with 100-240 VAC @ 50/60Hz external power supply |
| Cooling |
Dual fans |
| Size |
1/2W – 1.65” x 8” x 10” (Two will fit in a standard 1U rack space) |
| Environments |
Operating Temperature: 5°C to 50°C Relative Humidity: 5 to 90% Non-condensing |
Storage Temperature: -45°C to 105°C Relative Humidity: 5 to 90% Non-condensing |
|
| MTBF |
640,000 hours |
| Compliances |
FCC Class B; Canada ICES-003 Class B, CE Europe (EN55022/EN55024); Japan VCCI Class B) |
| Warranty |
3 years |
| SAS Switch Accessories |
SAS6160 1U Mounting Tray SAS6160 Replacement Power Supply Active Cables available in different lengths |
| Ordering Information |
LSI SAS6160 Switch P/N: LSI00269 |
>>
Expand
Product Brief (1)
>> Expand
LSI SAS Switch 6160
Size: 0.57M
Language: English
|
Oct 18, 2010 |
 |
|
|
|
Case Study (1)
>> Expand
The Pittsburgh Supercomputing Center Chooses LSI and Seneca Data Technologies to Archive Critical Data
LSI and Seneca Data improve performance and reduce costs with a multi-petabyte archive storage solution
Size: 0.69M
Language: English
|
Apr 15, 2012 |
 |
|
Compatibility Document (1)
>> Expand
LSI SAS6160 Switch Hardware Compatibility Matrix
LSI SAS6160 Switch Compatibility List
Version: Feb 2013
Size: 88.3K
Language: English
|
Feb 06, 2013 |
 |
|
FAQ Document (1)
>> Expand
LSI FAQ SASSwitch6160
The SAS6160 Switch power supply is universal, supporting from 100 to 240 VAC @ 50 or 60 Hz. The switch always includes a domestic US power cord. Power cords with an IEC320 C5 connector and appropriate wire gauge may be substituted, subject to local agency approvals, to support alternate power connections.
Version: July, 2012
Size: 0.51M
Language: English
|
Jul 31, 2012 |
 |
|
Product Guide (2)
>> Expand
Storage Adapter Product Selector Guide
Storage Adapter Product Selector Guide
Version: December 2012
Size: 0.90M
Language: English
|
Dec 03, 2012 |
 |
|
Storage Solutions Product Guide
Storage Solutions Product Guide 2012
Version: December 2012
Size: 2.98M
Language: English
|
Dec 03, 2012 |
 |
|
Product Sell Sheets (1)
>> Expand
LSI® SAS6160 Switch Sell Sheet
LSI® SAS6160 Switch Sell Sheet
Size: 0.92M
Language: English
|
Jul 29, 2012 |
 |
|
Quick Installation Guide (1)
>> Expand
LSISAS6160 SAS Switch QIG
Version: October 2010
Size: 57.0K
Language: English
|
Oct 12, 2010 |
 |
|
Release Notes (7)
>> Expand
Release_Notes_LSISAS6160_SAS_Switch_r201.14.00.00_Firmware
These release notes correspond to r201.14.00.00 of the LSISAS6160 SAS switch firmware.
Version: Version 1.0
Size: 0.68M
Language: English
|
Jul 02, 2012 |
 |
|
Release_Notes_LSISAS6160_SAS_Switch_r201.13.01.00_Point_Release_Firmware_P13
These release notes correspond to r201.13.01.00 of the LSISAS6160 SAS switch firmware.
Version: Version 1.0 Point Release
Size: 140.0K
Language: English
|
May 09, 2012 |
 |
|
LSISAS6160 SAS Switch r201.13.00.00 FW Release Notes
These release notes correspond to r201.13.00.00 of the LSISAS6160 SAS switch firmware.
Version: Version 1.0
Size: 207.3K
Language: English
|
Apr 22, 2012 |
 |
|
LSISAS6160 SAS Switch r200.11.02.00 FW Release Notes
These release notes correspond to r200.11.02.00 of the LSISAS6160 SAS switch firmware.
Version: Version 1.1, April 2012
Size: 245.7K
Language: English
|
Apr 16, 2012 |
 |
|
LSISAS6160 SAS Switch rr200.10.00.00 FW Release Notes
These release notes correspond to r200.10.00.00 of the LSISAS6160 SAS switch firmware.
Version: Version 1.1, July 2011
Size: 246.1K
Language: English
|
Aug 01, 2011 |
 |
|
LSISAS6160 SAS Switch r200.09.01.00 Firmware
These release notes correspond to r200.09.01.00 of the LSISAS6160 SAS switch firmware.
Version: Version 1.0, April 2011
Size: 121.3K
Language: English
|
May 18, 2011 |
 |
|
LSISAS6160 SAS Switch r201.12.00.00 FW Release Notes
These release notes correspond to r201.12.00.00 of the LSISAS6160 SAS switch firmware.
Version: Version 1.1, April 2012
Size: 211.9K
Language: English
|
Apr 11, 2011 |
 |
|
Solution Brief (2)
>> Expand
Combine SAS servers and storage with iSCSI over a single unified SAN
LSI and Chelsio work together to extend the benefits of SAS to existing IP based storage networks
Version: August 2012
Size: 435.6K
Language: English
|
Sep 01, 2012 |
 |
|
Academic Computing Solution Brief
Delivering data to harried administrators and classroom teachers alike at the fastest possible rate for the least possible cost is the dilemma faced by every school system IT team. Now, with the help of LSI storage technologies currently on the market, it is possible to use existing infrastructure for up to 13X better performance with a minimal investment.
Size: 2.31M
Language: English
|
Sep 28, 2011 |
 |
|
User Guide (1)
>> Expand
LSISAS6160 SAS Switch
Version: 1.8
Size: 6.45M
Language: English
|
Dec 19, 2012 |
 |
|
White Paper (1)
>> Expand
Deciding on a Host Interface Technology
Version: December 2010
Size: 1.08M
Language: English
|
Dec 13, 2010 |
 |
|
|
|
Storage eLearning Channel |
Click on the arrow on the right or left of the player screen to watch our videos on: - Installation of a 6Gb/s SAS Switch in a Rack Environment
- LSI 6Gb/s SAS Switch for Scalable, Sharable Storage
|
|
|
>>
Expand
Firmware (1)
>> Expand
LSI_SAS_6160_Firmware_P14 Point Release
LSI SAS 6160 Firmware P14 Point Release
Version: 201.14.03.00
Size: 2.8K
Language: English
|
Mar 07, 2013 |
 |
|
Software (3)
>> Expand
LSI_SAS_6160_Switch_Configuration_Scripts
LSI SAS 6160 Switch Configuration Scripts
Size: 2.7K
Language: English
|
Oct 19, 2011 |
 |
|
LSI_SAS_Switch_Recovery_Utility_P14
LSI SAS6160 Switch Recovery Utility
Version: 14.0.0.0
Size: 181.8K
Language: English
|
Jul 10, 2012 |
 |
|
Xip_Application_P13
Xip Application P13
Version: 13.0.0.0
Size: 2.82M
Language: English
|
Feb 06, 2012 |
 |
|
|
|
Cables and Accessories
LSI offers various internal cable options to make integration into your current system infrastructure as easy as possible. LSI also offers cache protection options for RAID controllers that protect against data loss in the event of a server or power failure by providing emergency power to the cache memory.
|
|
|
|
|