LSI SAS 9200-8e HBA - Low-profile, eight-port external 6Gb/s SATA +SAS PCIe 2.0 HBA
- Mid-range scalability for high performance applications
- Well-configured storage building block for core business applications like general ledger, SAP, ERP, or CRM
|
|
Product Banner
|
Product Features / Benefits
Features
- Two x4 external SFF8088 Mini-SAS connectors
- MD2 low profile form-factor design
Benefits
- Doubles the performance of previous generation SATA+SAS HBAs
- Environmentally friendly due to low-power consumption
- 6Gb/s SAS connectivity eases integration and broadens application by supporting legacy speeds and the SATA protocol
|
|
Product Specifications
|
|
| IO Controller |
LSI SAS2008/ Fusion MPT 2.0 |
| Storage Connectivity; Data Transfer Rates |
8 ports; 6Gb/s SAS 2.0 compliant |
| Host Bus |
x8 lane, PCI Express 2.0 compliant |
| PCI Data Burst Transfer Rates |
x8, PCIe, 4000 MB/s |
| Physical Dimensions |
Low Profile (2. 6" x 6.6") |
| Connectors |
Two mini-SAS external connectors (SFF8088) |
| Brackets |
Full height and low profile |
| Cable Support |
Passive Copper |
| PCI Card Type |
3.3 V Add-in Card |
| Operating Voltage |
+12V +/-8%; 3.3V +/-8% |
| PCI Power (Nominal) |
8 W typical (Airflow min 200 LFM) |
| Device Support |
512 Non-RAID SAS/SATA devices |
| Environments |
| Operating |
Storage |
| 0°C to 55°C |
-45°C to 105°C |
| 5 to 90% Non-condensing |
5 to 90% Non-condensing |
|
| MTBF |
>2,000,000 Hours |
| Regulatory Certifications |
EMC: Class B-US (CFR 47, P15B); Canada (ICES-003); Japan (V-3/02.04); Europe (EN55022/EN55024); Australia/New Zealand (AS/NZS 3548); Safety: EN60950; RoHS; WEEE |
| OS Support |
Microsoft Windows, Linux (SuSE , Red Hat), Solaris, VMware, FreeBSD See http://www.lsi.com/support/pages/downloads.aspx for details on versions |
| Warranty |
3 years; with advanced replacement option Free technical support at http://www.lsi.com/support/Pages/warrantyenhancedsupport.aspx |
|
|
|
>>
Expand
Product Brief (1)
>> Expand
LSI SAS 9200-8e Product Brief
Version: July 2012
Size: 0.74M
Language: English
|
Apr 09, 2011 |
 |
|
|
|
Compatibility Document (1)
>> Expand
Compatibility Report for 6Gb/s SATA+SAS HBAs
This represents basic compatibility and is only a guide to hardware which is known to function with the listed 6Gb/s SATA+SAS HBAs.
Version: May 2013
Size: 0.66M
Language: English
|
May 14, 2013 |
 |
|
Product Guide (2)
>> Expand
Storage Adapter Product Selector Guide
Storage Adapter Product Selector Guide
Version: December 2012
Size: 0.90M
Language: English
|
Dec 03, 2012 |
 |
|
Storage Solutions Product Guide
Storage Solutions Product Guide 2012
Version: December 2012
Size: 2.98M
Language: English
|
Dec 03, 2012 |
 |
|
Quick Installation Guide (1)
>> Expand
LSISAS9200-8e Quick Install Guide
Version: April 2011
Size: 91.6K
Language: English
|
Apr 14, 2011 |
 |
|
Solution Brief (1)
>> Expand
Academic Computing Solution Brief
Delivering data to harried administrators and classroom teachers alike at the fastest possible rate for the least possible cost is the dilemma faced by every school system IT team. Now, with the help of LSI storage technologies currently on the market, it is possible to use existing infrastructure for up to 13X better performance with a minimal investment.
Size: 2.31M
Language: English
|
Sep 28, 2011 |
 |
|
User Guide (2)
>> Expand
PCI Express to 6Gb/s SAS HBAs User Guide
This document describes the capabilities and characteristics, including electrical, environmental, functional, and performance characteristics, of the LSI PCIe to 6G SAS (6 gigabit) host bus adapters.
Version: May 2013
Size: 0.54M
Language: English
|
May 16, 2013 |
 |
|
LSI SAS 9200-8e PCI Express to 6Gb/s Serial Attached SCSI (SAS)
LSI SAS 9200-8e PCI Express to
6Gb/s Serial Attached SCSI (SAS)
Host Bus Adapter
Version: July 2011
Size: 244.9K
Language: English
|
Sep 13, 2011 |
 |
|
|
|
Storage eLearning Channel
|
Click on the arrow on the right or left of the player screen to watch our how-to videos on:
- Installing HBAs on Linux servers
- Installing HBAs on Windows servers
- Using HBAs for integrated mirroring
|
|
|
>>
Expand
BIOS (1)
>> Expand
UEFI_BSD_P16
UEFI BSD
Version: 07.23.01.00
Size: 1.41M
Language: English
|
Mar 05, 2013 |
 |
|
Driver (14)
>> Expand
Free_BSD_Driver_P16
FreeBSD 7.2.0, 7.4.0, 8.2.0, 8.3.0, 9.0.0 Driver
Version: 16.00.00.00
Size: 1.28M
Language: English
|
FreeBSD 7.2.0, 7.4.0, 8.2.0, 8.3.0, 9.0.0 |
Feb 28, 2013 |
 |
|
Linux_Driver_RH4_SLES9_P16
RHEL 4 and SLES 9 Driver
Version: 16.00.00.00-1
Size: 38.40M
Language: English
|
RHEL 4 and SLES 9 |
Mar 01, 2013 |
 |
|
Linux_Driver_RH5_SLES10_P16
RHEL5/6 and SLES10/11 Driver
Version: 16.00.00.00-1
Size: 744.76M
Language: English
|
RHEL5/6 and SLES10/11 |
Feb 28, 2013 |
 |
|
Solaris 10 - readme
Size: 0.6K
Language: English
|
Solaris 10 |
Oct 25, 2011 |
 |
|
VMware Driver Links
VMware Driver links
Version: 1.0.0.0
Size: 25.0K
Language: English
|
VMware |
Nov 07, 2012 |
 |
|
Driver-CD-ESX4_P16
VMware ESX/ESXi 4.x Driver
Version: 16.00.00.00.1vmw
Size: 0.62M
Language: English
|
VMware ESX/ESXi 4.x |
Apr 08, 2013 |
 |
|
Driver-CD-ESX5_P16
VMware ESX/ESXi 5.x Driver
Version: 16.00.00.00.1vmw
Size: 0.63M
Language: English
|
VMware ESX/ESXi 5.x |
Apr 02, 2013 |
 |
|
LSImpt_SAS_Windows_Server_2012_P16
Driver for Windows 2012
Version: 2.00.63.00
Size: 0.82M
Language: English
|
Windows 2012 |
May 01, 2013 |
 |
|
LSImpt_SAS2_Windows7_Windows_Server_2008_R2_P16
Driver for Windows7 and Windows Server 2008 R2.
Version: 2.00.63.00
Size: 2.40M
Language: English
|
Windows 7 and Windows Server 2008 R2 |
May 01, 2013 |
 |
|
LSImpt_SAS2_Windows8_P16
Driver for Windows 8
Version: 2.00.63.00
Size: 1.62M
Language: English
|
Windows 8 |
May 01, 2013 |
 |
|
LSImpt_SAS2_Windows_Server_2003_P16
Driver for Windows Server 2003
Version: 2.00.63.00
Size: 2.36M
Language: English
|
Windows Server 2003 |
May 01, 2013 |
 |
|
LSImpt_SAS2_Windows_Server_2008_P16
Driver for Windows Server 2008
Version: 2.00.63.00
Size: 2.40M
Language: English
|
Windows Server 2008 |
May 01, 2013 |
 |
|
LSImpt_SAS2_Windows_Vista_P16
Driver for Windows Vista.
Version: 2.00.63.00
Size: 1.48M
Language: English
|
Windows Vista |
May 01, 2013 |
 |
|
LSImpt_SAS2_Windows_XP_64bit_P16
Driver for Windows XP 64 bit.
Version: 2.00.63.00
Size: 0.73M
Language: English
|
Windows XP 64bit |
May 01, 2013 |
 |
|
Firmware (6)
>> Expand
9200_8e_Package_P16_IT_Firmware_BIOS_for_MSDOS_Windows
Package_P16_Firmware_BIOS_for_MSDOS_Windows
Version: 16.00.00.00
Size: 1.12M
Language: English
|
|
Feb 27, 2013 |
 |
|
Installer_P16_for_FreeBSD
FreeBSD Installer
Version: 16.00.00.00
Size: 0.53M
Language: English
|
FreeBSD |
Mar 01, 2013 |
 |
|
Installer_P16_for_Linux
Linux Installer
Version: 16.00.00.00
Size: 0.84M
Language: English
|
Linux |
Mar 01, 2013 |
 |
|
Installer_P16_for_Solaris
Solaris Installer
Version: 16.00.00.00
Size: 392.9K
Language: English
|
Solaris |
Mar 01, 2013 |
 |
|
Installer_P16_for_UEFI
UEFI Installer
Version: 16.00.00.00
Size: 369.2K
Language: English
|
UEFI |
Mar 01, 2013 |
 |
|
Installer_P16_for_Vmware_ESX50
VMware ESX5.0 Installer
Version: 16.00.00.00
Size: 0.71M
Language: English
|
VMware ESX5.0 |
Mar 01, 2013 |
 |
|
Management Software and Tools (5)
>> Expand
Latest LSISAS2108/2208 MegaRAID Storage Manager
MR 5.7
Version: 13.04.03.01
Size: 72.71M
Language: English
|
Linux 32-bit |
May 30, 2013 |
 |
|
Latest LSISAS2108/2208 MegaRAID Storage Manager
MR 5.7
Version: 13.04.03.01
Size: 66.72M
Language: English
|
Linux 64-bit |
May 30, 2013 |
 |
|
Latest LSISAS2108/2208 MegaRAID Storage Manager
MR 5.7
Version: 13.04.03.01
Size: 86.64M
Language: English
|
Solaris 10 32-bit |
May 30, 2013 |
 |
|
Latest LSISAS2108/2208 MegaRAID Storage Manager
MR 5.7
Version: 13.04.03.01
Size: 87.12M
Language: English
|
Solaris 11 32-bit |
May 30, 2013 |
 |
|
Latest LSISAS2108/2208 MegaRAID Storage Manager
MR 5.7
Version: 13.04.03.01
Size: 73.05M
Language: English
|
Windows |
May 30, 2013 |
 |
|
|
|
Cables and Accessories
LSI offers various internal cable options to make integration into your current system infrastructure as easy as possible. LSI also offers cache protection options for RAID controllers that protect against data loss in the event of a server or power failure by providing emergency power to the cache memory.
|
|
|
|
|
|