Product Features / Benefits Features
- Four internal and Four external 6Gb/s SAS +SATA ports
- 8 lanes, PCI Express 3.0
- Low-profile form-factor design
- One x 4 internal mini-SAS (SFF8087), One x4 external mini-SAS (SFF8088)
- LSISAS2308 6Gb/s SAS+SATA Controller
- Support for up to 256 SAS or SATA end devices
- Fusion-MPT™ 2.0 architecture can achieve more than 700,000 I/Os per second
- Supports major operating systems
- RoHS compliant
- Three-year standard warranty
Benefits
- Designed to provide state of the art connectivity for servers and appliances with internal storage and the ability to add external storage
- 8 lanes of PCI Express 3.0 provides faster signaling for high-bandwidth applications
- High performance with 6Gb/s data transfer rates
- Mac OS support for additional integration flexibility
Product Specifications
|
|
| IO Controller |
LSI SAS2308 / Fusion MPT 2.0 |
| Storage Connectivity; Data Transfer Rates |
8 ports, 6Gb/s SAS 2.1 Compliant |
| SAS Bandwidth |
Half Duplex 600 MB/s per lane |
| Port Configurations |
4 ea, x1 internal ports (individual drives); 4 ea, x1 external ports 1ea, x4 external wide port |
| Host Bus |
x8 lane, PCI Express 3.0 compliant |
| PCI Data Burst Transfer Rates |
Half Duplex x8, PCIe, 8000 MB/s |
| Physical Dimensions |
Low Profile (2.6" x 6.6") |
| Connectors |
One x 4 internal mini-SAS (SFF8087), One x4 external mini-SAS (SFF8088) |
| Brackets |
Full height and low profile |
| Cable Support |
Passive Copper |
| Operating Voltage |
+12V +/-8%; 3.3V +/-8% |
| PCI Power (Nominal) |
9.8W typical, Airflow 200 LFM |
| Device Support |
256 Non-RAID SAS/SATA devices |
| Environmental |
| Operating |
Storage |
| 0°C to 55°C |
-45°C to 105°C |
| 5 to 90% Non-condensing |
5 to 90% Non-condensing |
|
| MTBF |
>2,000,000 hours |
| Regulatory Certifications |
EMC: Class B-US (CFR 47, P15B); Canada (ICES-003); Japan (V-3/02.04); Europe (EN55022/EN55024); Australia/New Zealand (AS/NZS 3548); Safety: EN60950; RoHS; WEEE |
| OS Support |
Microsoft Windows, Linux (SuSE , Red Hat), Solaris, VMware, FreeBSD See http://www.lsi.com/support/pages/downloads.aspx for details on versions |
| Warranty |
3 years; with advanced replacement option Free technical support at http://www.lsi.com/support/Pages/warrantyenhancedsupport.aspx |
|
|
>>
Expand
Product Brief (1)
>> Expand
LSI SAS9207-4i4e Product Brief
LSI SAS 9207-4i4e host bus adapter provides a high performance solution for internal and external storage connections in 1U/2U servers and workstations.
Version: February 2013
Size: 0.54M
Language: English
|
Feb 07, 2013 |
 |
|
|
|
Certifications (4)
>> Expand
Letter of Volatility for LSI HBA Products
Size: 19.7K
Language: English
|
Nov 12, 2012 |
 |
|
WEEE Statement
Size: 85.2K
Language: English
|
Nov 12, 2012 |
 |
|
RoHS for LSI HBA 6Gb/s Products
Size: 40.6K
Language: English
|
Nov 12, 2012 |
 |
|
UL (US) for LSI SAS 9207 series HBAs
Size: 104.4K
Language: English
|
Nov 12, 2012 |
 |
|
Compatibility Document (1)
>> Expand
Compatibility Report for 6Gb/s SATA+SAS HBAs
This represents basic compatibility and is only a guide to hardware which is known to function with the listed 6Gb/s SATA+SAS HBAs.
Version: May 2013
Size: 0.66M
Language: English
|
May 14, 2013 |
 |
|
FAQ Document (1)
>> Expand
LSI SAS 9207 series of HBAs - Frequently Asked Questions
Version: June 2012
Size: 0.57M
Language: English
|
Jun 26, 2012 |
 |
|
Product Sell Sheets (1)
>> Expand
LSI SAS 9207 Series HBA Sell Sheet
Version: July 2012
Size: 0.75M
Language: English
|
Jul 12, 2012 |
 |
|
Quick Installation Guide (1)
>> Expand
LSI SAS 9207-4i4e Quick Installation Guide
Thank you for purchasing the LSI SAS 9207-4i4e PCI Express (PCIe®) to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapter (HBA). Please take a few minutes ead this quick installation guide before you install the LSI SAS 9207-4i4e HBA.
Size: 277.5K
Language: English
|
May 24, 2012 |
 |
|
User Guide (1)
>> Expand
LSI SAS9207-4i4e User Guide
The LSI SAS 9207-4i4e PCI Express (PCIe®)-to-Serial Attached SCSI (SAS) host bus adapter (HBA), referred to as the LSI SAS 9207-4i4e HBA, provides high-performance internal and external storage connectivity for servers and workstations.
Version: May 2012
Size: 155.7K
Language: English
|
Jun 05, 2012 |
 |
|
|
|
Storage eLearning Channel |
Click on the arrow on the right or left of the player screen to watch our how-to videos on: - Installing HBAs on Linux servers
- Installing HBAs on Windows servers
- Using HBAs for integrated mirroring
|
|
|
>>
Expand
BIOS (1)
>> Expand
UEFI_BSD_P16
UEFI BSD
Version: 07.23.01.00
Size: 1.41M
Language: English
|
Mar 05, 2013 |
 |
|
Driver (13)
>> Expand
Free_BSD_Driver_P16
FreeBSD 7.2.0, 7.4.0, 8.2.0, 8.3.0, 9.0.0 Driver
Version: 16.00.00.00
Size: 1.28M
Language: English
|
FreeBSD 7.2.0, 7.4.0, 8.2.0, 8.3.0, 9.0.0 |
Feb 28, 2013 |
 |
|
Linux_Driver_RH4_SLES9_P16
RHEL 4 and SLES 9 Driver
Version: 16.00.00.00-1
Size: 38.40M
Language: English
|
RHEL 4 and SLES 9 |
Mar 01, 2013 |
 |
|
Linux_Driver_RH5_SLES10_P16
RHEL5/6 and SLES10/11 Driver
Version: 16.00.00.00-1
Size: 744.76M
Language: English
|
RHEL5/6 and SLES10/11 |
Feb 28, 2013 |
 |
|
VMware Driver Links
VMware Driver links
Version: 1.0.0.0
Size: 25.0K
Language: English
|
VMware |
Nov 07, 2012 |
 |
|
Driver-CD-ESX4_P16
VMware ESX/ESXi 4.x Driver
Version: 16.00.00.00.1vmw
Size: 0.62M
Language: English
|
VMware ESX/ESXi 4.x |
Apr 08, 2013 |
 |
|
Driver-CD-ESX5_P16
VMware ESX/ESXi 5.x Driver
Version: 16.00.00.00.1vmw
Size: 0.63M
Language: English
|
VMware ESX/ESXi 5.x |
Apr 02, 2013 |
 |
|
LSImpt_sas_Windows_Server_2012_P15
Driver for Windows 2012
Version: 2.00.60.02
Size: 0.81M
Language: English
|
Windows 2012 |
Jan 31, 2013 |
 |
|
LSImpt_SAS2_Windows7_Windows_Server_2008_R2_P16
Driver for Windows7 and Windows Server 2008 R2.
Version: 2.00.63.00
Size: 2.40M
Language: English
|
Windows 7 and Windows Server 2008 R2 |
May 01, 2013 |
 |
|
LSImpt_SAS2_Windows8_P16
Driver for Windows 8
Version: 2.00.63.00
Size: 1.61M
Language: English
|
Windows 8 |
May 01, 2013 |
 |
|
LSImpt_SAS2_Windows_Server_2003_P16
Driver for Windows Server 2003
Version: 2.00.63.00
Size: 2.36M
Language: English
|
Windows Server 2003 |
May 01, 2013 |
 |
|
LSImpt_SAS2_Windows_Server_2008_P16
Driver for Windows Server 2008
Version: 2.00.63.00
Size: 2.40M
Language: English
|
Windows Server 2008 |
May 01, 2013 |
 |
|
LSImpt_SAS2_Windows_Vista_P16
Driver for Windows Vista.
Version: 2.00.63.00
Size: 1.48M
Language: English
|
Windows Vista |
May 01, 2013 |
 |
|
LSImpt_SAS2_Windows_XP_64bit_P16
Driver for Windows XP 64 bit.
Version: 2.00.63.00
Size: 0.73M
Language: English
|
Windows XP 64bit |
May 01, 2013 |
 |
|
Firmware (6)
>> Expand
9207_4i4e_Package_P16_IT_Firmware_BIOS_for_MSDOS_Windows
Package_P16_Firmware_BIOS_for_MSDOS_Windows
Version: 16.00.00.00
Size: 1.62M
Language: English
|
|
Feb 27, 2013 |
 |
|
Installer_P16_for_FreeBSD
FreeBSD Installer
Version: 16.00.00.00
Size: 0.53M
Language: English
|
FreeBSD |
Mar 01, 2013 |
 |
|
Installer_P16_for_Linux
Linux Installer
Version: 16.00.00.00
Size: 0.84M
Language: English
|
Linux |
Mar 01, 2013 |
 |
|
Installer_P16_for_Solaris
Solaris Installer
Version: 16.00.00.00
Size: 392.9K
Language: English
|
Solaris |
Mar 01, 2013 |
 |
|
Installer_P16_for_UEFI
UEFI Installer
Version: 16.00.00.00
Size: 369.2K
Language: English
|
UEFI |
Mar 01, 2013 |
 |
|
Installer_P16_for_Vmware_ESX50
VMware ESX5.0 Installer
Version: 16.00.00.00
Size: 0.71M
Language: English
|
VMware ESX5.0 |
Mar 01, 2013 |
 |
|
Management Software and Tools (12)
>> Expand
MegaRAID Storage Manager - Linux 64 bit - 5.6
MegaRAID Storage Manager
Version: 13.01.04-00
Size: 63.48M
Language: English
|
Linux x64 |
Mar 02, 2013 |
 |
|
MegaRAID Storage Manager - Linux 32 bit - 5.6
MegaRAID Storage Manager
Version: 13.01.04-00
Size: 68.17M
Language: English
|
Linux x86 |
Mar 02, 2013 |
 |
|
MSM_MR_5_3_Linux_x86
MSM for Linux x86
Version: 12.05.03.00
Size: 54.97M
Language: English
|
RHEL/SLES |
May 23, 2012 |
 |
|
MSM_MR_5_3_Linux_x64
MSM for Linux x64
Version: 12.05.03.00
Size: 48.63M
Language: English
|
RHEL/SLES |
May 23, 2012 |
 |
|
MSM_MR_5_3_Solaris_10_SPARC
MSM for Solaris 10 SPARC
Version: 12.05.03.00
Size: 59.13M
Language: English
|
Solaris 10 SPARC |
May 24, 2012 |
 |
|
MegaRAID Storage Manager - Solaris 10 - 5.6
MegaRAID Storage Manager
Version: 12.05.03-00
Size: 75.38M
Language: English
|
Solaris 10 x86 |
Mar 02, 2013 |
 |
|
MSM_MR_5_3_Solaris_10_x86
MSM for Solaris 10 x86
Version: 12.05.03.00
Size: 54.23M
Language: English
|
Solaris 10 x86 |
May 24, 2012 |
 |
|
MSM_MR_5_3_Solaris_11_SPARC
MSM for Solaris 11 SPARC
Version: 12.05.03.00
Size: 53.05M
Language: English
|
Solaris 11 SPARC |
May 24, 2012 |
 |
|
MegaRAID Storage Manager - Solaris 11 - 5.6
MegaRAID Storage Manager
Version: 13.01.04-00
Size: 76.75M
Language: English
|
Solaris 11 x86 |
Mar 02, 2013 |
 |
|
MSM_MR_5_3_Solaris_11_x86
MSM for Solaris 11 x86
Version: 12.05.03.00
Size: 54.68M
Language: English
|
Solaris 11 x86 |
May 24, 2012 |
 |
|
MegaRAID Storage Manager - Windows - 5.6
MegaRAID Storage Manager
Version: 13.01.04-00
Size: 68.47M
Language: English
|
Windows |
Mar 02, 2013 |
 |
|
MSM_MR_5_3_Windows
MSM for Windows
Version: 12.05.03.00
Size: 44.28M
Language: English
|
Windows 2000, Windows 2003, Windows XP, Windows Vista, Windows 2008, Windows 7 |
May 23, 2012 |
 |
|
Miscellaneous (1)
>> Expand
SAS2IRCU_P16
15.00.00.00
Version: 16.00.00.00
Size: 2.76M
Language: English
|
DOS, Windows, Linux, Solaris, FreeBSD, EFI_EBC |
Mar 01, 2013 |
 |
|
|
|
Cables and Accessories
LSI offers various internal cable options to make integration into your current system infrastructure as easy as possible. LSI also offers cache protection options for RAID controllers that protect against data loss in the event of a server or power failure by providing emergency power to the cache memory.
|
|
|
|
|